CONTROL PANELS
The cycle LED will light up and the first setting STEP1 DURATION will scroll on the
display, and alternate every 5 seconds with its value.
Use the UP and DOWN keys to adjust a setting. Once the wanted value is displayed,
pressing the OFF key again will bring up the next setting. Change all settings for as many
steps as required (up to 3 per Cycle). If step duration is set to 0, then all following
parameters are ignored and the unit returns to the previous mode. It is assumed that
programming for this particular cycle is finished.
Note that in all setting descriptions below, X can be 1 , 2 , or 3 , depending on the current
step being programmed.
Step Duration
This is the time that the unit will remain in the current step. If there is only 1 step defined
for the cycle, this also corresponds to the total cycle time. If a step has 0 duration, the
current step and all following ones are not programmable (i.e. not used). If step 1 is set to 0,
then the cycle is not defined and pressing the Cycle key will not do anything.
Setting name: STEP X DURATION
Allowed values: 0:00 to 9.59
Default value: 1:00
Step Temperature
The wash tank’s water temperature is defined here.
Setting name: STEP X TEMPERATURE
Allowed values: 100˚ f to 125˚ f (38˚ c to 52˚ c)
Default value: 115˚ f (46˚ c)
Step Pump Speed
This is the pump speed during the particular step.
Setting name: STEP X PUMP SPEED
Allowed values: LOW, MED, or HIGH
Default value: LOW